|
Bio-Rad
charge coupled device camera Charge Coupled Device Camera, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pm39980226-100-9-14?v=Bio-Rad Average 99 stars, based on 1 article reviews
charge coupled device camera - by Bioz Stars,
2026-07
99/100 stars
|
Buy from Supplier |
|
Bio-Rad
chemidoc mp imaging system Chemidoc Mp Imaging System, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pm27119279__cb6b00190_si_001-54-14-24?v=Bio-Rad Average 99 stars, based on 1 article reviews
chemidoc mp imaging system - by Bioz Stars,
2026-07
99/100 stars
|
Buy from Supplier |
|
Bio-Rad
bio rad chemidoc mp station ![]() Bio Rad Chemidoc Mp Station, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pmc12790305-105-18-18?v=Bio-Rad Average 99 stars, based on 1 article reviews
bio rad chemidoc mp station - by Bioz Stars,
2026-07
99/100 stars
|
Buy from Supplier |
|
Hamamatsu
digital cooled camera orcaii-erg2 ![]() Digital Cooled Camera Orcaii Erg2, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pmc06544241-77-23-25?v=Hamamatsu Average 90 stars, based on 1 article reviews
digital cooled camera orcaii-erg2 - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Carl Zeiss
axiovert 200m fluorescence microscope ![]() Axiovert 200m Fluorescence Microscope, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pmc06544241-77-11-15?v=Carl+Zeiss Average 90 stars, based on 1 article reviews
axiovert 200m fluorescence microscope - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Bio-Rad
ethidium bromide ![]() Ethidium Bromide, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pmc06400010-93-17-30?v=Bio-Rad Average 96 stars, based on 1 article reviews
ethidium bromide - by Bioz Stars,
2026-07
96/100 stars
|
Buy from Supplier |
|
Tecan Systems
spark multimode microplate reader ![]() Spark Multimode Microplate Reader, supplied by Tecan Systems, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pmc12790305-105-5-4?v=Tecan+Systems Average 99 stars, based on 1 article reviews
spark multimode microplate reader - by Bioz Stars,
2026-07
99/100 stars
|
Buy from Supplier |
|
DIAGENODE DIAGNOSTICS
bioruptor pico microtubes ![]() Bioruptor Pico Microtubes, supplied by DIAGENODE DIAGNOSTICS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/chemidoc+cooled+camera/pm37889758-72-96-104?v=DIAGENODE+DIAGNOSTICS Average 90 stars, based on 1 article reviews
bioruptor pico microtubes - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Advanced Healthcare Materials
Article Title: Myeloperoxidase Luminol Reaction – A Novel Faecal Assay for Predicting Colonoscopy Findings in Patients with Ulcerative Colitis: A Pilot Cross‐Sectional Clinical Study
doi: 10.1002/adhm.202501825
Figure Lengend Snippet: Representation & quantification of MPOLR luminosity in faecal samples. Representative luminescence images of healthy faecal samples spiked with 0 µg mL −1 (A), 100 µg mL −1 (B), or 200 µg mL −1 (C) MPO. D) Quantitative analysis of spiked MPO titrations (n = experimental repeats). E) Correlation between MPOLR device and Bio‐Rad ChemiDoc MP station in UC (n = 20) faecal samples. The MPOLR device used a Raspberry Pi SC0818 HQ camera (12.3 MP Sony IMX477 sensor) with 120 s exposure; the ChemiDoc station used a 6 MP cooled CCD with 300 s exposure. All experiments were repeated in triplicate. Data are represented asmean ± SD. ** p ≤ 0.01; *** p ≤ 0.001.
Article Snippet: Chemiluminescence detected using the Tecan Spark Multimode Microplate Reader (kinetic analysis with peak luminescence occurring within 3–15 s),
Techniques: